Colorlight H10FN 10-channel fiber conversion
The Colorlight H10FN connects ten Neutrik gigabit RJ45 channels to one opticalCON DUO fiber interface rated up to 10 Gb/s. It uses single-mode twin-core fiber and is documented with a Colorlight Z6 PRO connection example.
H10FN specifications
Distance clarification: the original listing stated 10 km, but the linked V1.4 specification dated April 16, 2020 states 2 km. The table below follows that document. Verify the supplied optical module before specifying a different link distance.
| Parameter | Specification |
|---|---|
| Ethernet ports | 10 Neutrik RJ45 ports; up to 1 Gb/s per channel |
| Fiber interface | 1 Neutrik opticalCON DUO; compatible with LC-LC |
| Optical data rate | Up to 10 Gb/s |
| Fiber mode | Single-mode twin-core |
| Transmission distance | 2 km in the linked V1.4 specification |
| Input voltage | AC 100–240 V |
| Operating temperature | 0 to +70 °C |
| Optical feature | Hot-pluggable, as specified |
Installation planning
Check optical connector compatibility, module ratings and the fiber route at both ends. The 10 Gb/s optical rating is separate from the 1 Gb/s rate of each RJ45 channel. Use the connection diagram in the PDF to review the sender and Ethernet channel arrangement.
Product photo

Specification download
Download the H10FN V1.4 specification
Frequently asked questions
Is the H10FN transmission distance 2 km or 10 km?
The linked V1.4 specification states 2 km in both its features and parameter table. The previous product text stated 10 km. This page follows V1.4; confirm the supplied optical hardware if a longer link is required.
Which fiber connector does H10FN use?
It has one Neutrik opticalCON DUO interface, listed as compatible with an LC-LC interface. The specification calls for single-mode twin-core fiber.
How many Ethernet channels are available?
H10FN has ten Neutrik RJ45 Ethernet ports, each rated up to 1 Gb/s. The optical interface supports up to 10 Gb/s.
Can H10FN work with Z6 PRO?
The V1.4 specification includes a connection diagram with the Z6 PRO. Confirm the exact fiber module and port assignment for the intended installation.
What input voltage and operating temperature are specified?
V1.4 lists AC 100–240 V input and an operating temperature range of 0 to +70 °C. It does not provide a rated power-consumption figure.