Product overview
The Linsn RV926 LED receiving card integrates sixteen HUB75 16-pin connectors, so a separate HUB board is not needed for the documented interface. It outputs 32 RGB data groups and supports up to 32-scan operation. The linked RV926 V1.1 manual specifies both general loading limits and a separate limit when calibration is enabled.
Product specifications
| Parameter | Specification |
|---|---|
| Model / manual | RV926; V1.1, March 2019 |
| Module connectors | 16 × HUB75, 16-pin |
| RGB data groups | 32 |
| Scan support | Up to 32 scan |
| Maximum loading | 256 × 1024 or 512 × 512 pixels |
| Calibration loading limit | Up to 384 × 288 pixels |
| Decoding | 138 decoding; 595 serial decoding |
| Calibration functions | Pixel-by-pixel brightness/color calibration; single-card color-space conversion |
| Driver support | General driver ICs and most PWM driver ICs, per manual |
| Maintenance functions | RCG readback; network-cable BER test |
| Supply | 5 V rated; 4.5–5.5 V |
| Rated current / power | 0.80 A / 4.0 W |
| Operating conditions | −20°C to +75°C; 0–95% humidity |
Cabinet wiring and calibration
The manual describes a normal mode using eight connectors and a 32-data-group mode using sixteen output connectors. Match the working mode, HUB75 pinout and module scan configuration before connecting the cabinet.
For calibration, use the specified 384 × 288 limit rather than the larger general loading figures. The manual also requires the receiver cascade direction to be horizontal; follow its wiring diagram for the installation.
The manufacturer describes the RV926 as the same size as, and compatible with, RV908 and compares it with RV901 plus a HUB75 board. This does not remove the need to check pin assignment, driver IC, scan mode and configuration files when replacing a card.


Frequently asked questions
1. Does the RV926 need a separate HUB75 board?
The RV926 has sixteen HUB75 16-pin connectors on board. The manual states that an extra HUB card is not required for this interface.
2. How many pixels can one RV926 control?
The manual lists 256 × 1024 or 512 × 512 pixels for general loading. It separately limits calibration operation to 384 × 288 pixels.
3. Can the RV926 replace an RV908 receiving card?
The manual describes RV926 as compatible with RV908 and the same size. Before replacement, check the module pinout, scan mode, driver IC and receiving-card configuration.
4. How should RV926 cards be cascaded?
The V1.1 manual specifies horizontal cascading. Follow the diagram in the downloadable specification and the screen’s configured cabinet mapping.